E-28—Qualification of electricity meters for a lengthened initial reverification period of 10 years

Category: Electricity
Issue date: 2024-03-05
Effective date: 2024-03-05
Revision number: 17
Supersedes: E-28 (rev. 16)


Table of contents


1.0 Scope

This bulletin applies to electricity meters qualified for a conditional and unconditional 10-year initial reverification period pursuant to Measurement Canada specifications S-EG-01 and S-S-05.

2.0 Purpose

The purpose of this bulletin is to officially communicate the electronic electricity meters that have been conditionally and unconditionally qualified for a 10-year initial reverification period pursuant to Measurement Canada specifications S-EG-01 and S-S-05, and to communicate those meters that no longer qualify for a lengthened initial reverification period.

3.0 References

4.0 Initial reverification period tables

For all electricity meters listed in the three tables below, qualification is applicable to all the service configurations, including the voltage and current ratings, indicated for each model specified in the Service Configurations section of the Notice of Approval (NOA). If the NOA has not been updated to the current format, this information is listed in other sections of the NOA.

Note: Click on the approval number in the tables to access the Notice of Approval Database search page. From this page, enter the number in the "Approval number" field to access the NOA of the specific meter and view the information on configurations and ratings.

Table 1: Electricity meters qualified for an unconditional 10-year initial reverification period
Manufacturer Model(s) Approval no. Configurations/Ratings Applicability
Accuenergy
(Canada) Inc.
  • AcuRev 1312
AE-2269 Rev. 3 As per NOA Unconditional 10‑year initial reverification period for all meters.
Aclara Meters LLC.
  • kV2
  • kV2n
  • kV2e
  • kV2ce
  • kV2c
  • kV2c+
  • kV2c EPS
  • kV2c+ EPS
AE-1059 Rev. 42 As per NOA Unconditional 10‑year initial reverification period for all meters.
Aclara Meters LLC. I-210 AE-1342 Rev. 7 As per NOA Unconditional 10‑year initial reverification period for all meters.
Aclara Meters LLC.
  • I-210+
  • I-210+n
AE-1517 Rev. 28 As per NOA Unconditional 10‑year initial reverification period for all meters.
Aclara Meters LLC.
  • I-210+c
  • I-210+ce
  • I-210+cn
AE-1652 Rev. 20 As per NOA Unconditional 10‑year initial reverification period for all meters.
Carma Corp.
  • Meter Manager T2mA
  • exclusively
E-0266 Rev. 18 As per NOA Unconditional 10‑year initial reverification period applicable to meters verified on or after May 18, 2012.
Elster Metering
  • ALPHA 1
  • A1*
  • A1D*
  • A1T*
  • *(A, L, Q, +) /
  • (P, M, Z, S, A)
  • Only model/type designations followed by a "+" sign.
AE-0541 Rev. 8 As per NOA Unconditional 10‑year initial reverification period for all meters.
Elster Metering
  • ALPHA 1
  • A1K*
  • A1R*
  • *(A, L, Q, +)
  • /(P, M, Z, S, A)
  • Only model/type designations followed by a "+" sign.
AE-0580 Rev. 9 As per NOA Unconditional 10‑year initial reverification period for all meters.
Elster Metering
  • ALPHA 1
  • A1*
  • A1D*
  • A1T*
  • A1K*
  • A1R*
  • *(A, L, Q, +) /
  • (P, M, Z, S, A)
  • Only model/type designations followed by a "+" sign.
AE-0601 Rev. 8 As per NOA Unconditional 10‑year initial reverification period for all meters.
Elster Metering
  • ALPHA 3
  • A3K
  • A3D
  • A3T
  • A3R
  • (Q, L, N, C or A model designations)
AE-1168 Rev. 32 As per NOA Unconditional 10‑year initial reverification period for all meters.
Elster Metering
  • REX
  • R1
  • R1S
  • R1SD
AE-1320 Rev. 3 As per NOA Unconditional 10‑year initial reverification period for all meters.
Elster Metering
  • REX2
  • R2S
  • R2SD
  • gREX
AE-1579 Rev. 13 As per NOA Unconditional 10‑year initial reverification period for all meters.
Elster Metering.
  • RU
  • RUD
AE-1976 Rev.14 As per NOA Unconditional 10‑year initial reverification period for all meters verified on or after May 7, 2013.
Intellimeter
Canada Inc.
  • MP-636 INC
  • MP-636 EXTC
AE-1589 As per NOA Unconditional 10‑year initial reverification period for all meters.
Intellimeter
Canada Inc.
  • i-meter 45
AE-2087 Rev.1 As per NOA Unconditional 10‑year initial reverification period for all meters.
Itron Inc.
  • C1S
  • CN1S
  • C1SD
  • C1ST
  • C1SL
  • CN1SD
  • CN1ST
  • CN1SL
  • C1SX
  • CN1SX
AE-0920 Rev. 32 As per NOA Unconditional 10‑year initial reverification period for all meters.
Itron Inc. Sentinel AE-1132 Rev. 19 As per NOA Unconditional 10‑year initial reverification period for all meters.
Itron Inc.
  • CP1S
  • CP1SR
  • CP1SD
  • CP1ST
  • CP1SL
  • CP1SDR2
  • CP1STR2
  • CP1SLR2
  • CP1SDR3
  • CP1STR3
  • CP1SLR3
  • CP1A
  • CP1AR
  • CP1AD
  • CP1AT
  • CP1AL
  • CP1ADR2
  • CP1ATR2
  • CP1ALR2
  • CP1ADR3
  • CP1ATR3
  • CP1ALR3
AE-1466 Rev. 14 As per NOA Unconditional 10‑year initial reverification period for all meters.
Itron Inc.
  • CVSO
  • CVSOD
  • CNVSOD
  • CVSOR
AE-1498 Rev. 7 As per NOA Unconditional 10‑year initial reverification period for all meters.
Itron Inc.
  • C2SO
  • C2SOD
  • CN2SO
  • CN2SOD
  • C2SOS
  • C2SODS
  • CN2SOS
  • CN2SODS
AE-1631 Rev. 15 As per NOA Unconditional 10‑year initial reverification period for all meters.
Itron Inc.
  • CP2SO
  • CP2SOS
  • CP2SOA
  • CP2SOAS
AE-1822 Rev. 16 As per NOA Unconditional 10‑year initial reverification period applicable to meters verified on or after January 1, 2011.
Itron Inc.
  • C1S
  • CN1S
  • C1SR
  • CN1SR
  • C1SD/T/L(R)(I)
  • CN1SD/T/L(R)
AE-2220 Rev. 4 As per NOA Unconditional 10‑year initial reverification period applicable to meters verified on or after April 20, 2016.
Itron Inc.
  • C2SO
  • C2SOD
  • CN2SO
  • CN2SOD
  • C2SOS
  • C2SODS
  • CN2SOS
  • CN2SODS
AE-2281 Rev. 4 As per NOA Unconditional 10‑year initial reverification period for all meters.
Itron Inc.
  • C2SRV
  • C2SRVD
  • CN2SRV
  • CN2SRVD
AE-2537 As per NOA Unconditional 10‑year initial reverification period for all meters.
Itron Inc.
  • C2SRV
  • C2SRVD
  • CN2SRV
  • CN2SRVD
AE-2538 As per NOA Unconditional 10‑year initial reverification period for all meters.
Landis + Gyr Inc.
  • RXS4
  • RXS4e
  • RXRS4
  • RXRS4e
  • AXS4
  • AXS4e
  • AXLS4
  • AXLS4e
  • AXRS4
  • AXRS4e
AE-0764 Rev. 23 As per NOA Unconditional 10‑year initial reverification period for all meters.
Landis + Gyr Inc. Focus ALF AE-1356 Rev. 6 As per NOA Unconditional 10‑year initial reverification period for all meters.
Landis + Gyr Inc.
  • Focus ALF
  • Focus II
AE-1559 Rev. 21 As per NOA Unconditional 10‑year initial reverification period for all meters.
Landis + Gyr Inc.
  • FOCUS AX
  • FOCUS AX-SD
  • FOCUS AXR
  • FOCUS AXR-SD
  • FOCUS RXR
  • FOCUS RXR-SD
AE-1641 Rev. 30 As per NOA Unconditional 10‑year initial reverification period for all meters.
Landis + Gyr Inc.
  • FOCUS AX
  • FOCUS AXR
  • FOCUS AX-SD
  • FOCUS AXR-SD
  • FOCUS RXR
  • FOCUS RXR-SD
AE-1723 Rev. 22 As per NOAs Unconditional 10‑year initial reverification period applicable to meters.
Landis + Gyr Inc.
  • FOCUS AXe
  • FOCUS AXRe
  • FOCUS AXe-SD
  • FOCUS AXRe-SD
  • FOCUS RXe
  • FOCUS RXRe
  • FOXUS RXe-SD
  • FOCUS RXRe-SD
AE-1967 Rev. 24 As per NOA Unconditional 10‑year initial reverification period applicable to meters verified on or after April 5, 2013.
Landis + Gyr Inc.
  • FOCUS AX
  • FOCUS AXR
  • FOCUS AX-SD
  • FOCUS AXR-SD
AE-2041 Rev. 11 As per NOA Unconditional 10‑year initial reverification period applicable to meters verified on or after May 12, 2014.
Landis + Gyr Inc.
  • E650 S4x RXR
  • E650 S4x RXR-8
AE-2112 Rev. 23 As per NOA Unconditional 10‑year initial reverification period applicable to meters verified on or after Jan 26, 2015.
Landis + Gyr Inc.
  • FOCUS AXe
  • FOCUS AXRe
  • FOCUS AXe-SD
  • FOCUS AXRe-SD
  • FOCUS RXe
  • FOCUS RXRe
  • FOXUS RXe-SD
  • FOCUS RXRe-SD
AE-2398 Rev. 9 As per NOA Unconditional 10‑year initial reverification period applicable to meters verified on or after July 26, 2018.
Landis + Gyr Inc. E650 S4x RXR AE-2402 Rev. 10 As per NOA Unconditional 10‑year initial reverification period applicable to meters verified on or after August 23, 2018.
Power Measurement Limited / Schneider Electric 8600 ION exclusively AE-0924 Rev. 12 As per NOA Unconditional 10‑year initial reverification period for all meters manufactured after April 18, 2013, or modified with the materials identified in Modification Acceptance Letter MAL-E396.
Note: Contact Measurement Canada or Schneider Electric for a complete listing of meters that qualified for an unconditional 10-year initial reverification period prior to April 18, 2013.
Power Measurement Limited / Schneider Electric ION8650 AE-1922 Rev. 5 As per NOA Unconditional 10‑year initial reverification period applicable to meters verified on or after January 1, 2013.
Quadlogic Controls Corp.
  • MC-5
  • MC-5C
AE-1148 Rev. 5 As per NOA Unconditional 10‑year initial reverification period for all meters.
Sensus Metering Systems Inc.
  • iCon
  • iCon Flexnet 530-X
  • iCon RadioRead
  • 530-E MXU
  • iCon Sensus
AE-1145 Rev. 7 As per NOA Unconditional 10‑year initial reverification period for all meters.
Sensus Metering Systems
  • iSA2
  • iNA2
AE-1611 Rev. 4 As per NOA Unconditional 10‑year initial reverification period for all meters.
Sensus Metering Systems
  • iCon iSA3
  • iCon iNA3
AE-1718 Rev. 16 As per NOA Unconditional 10‑year initial reverification period applicable to meters verified on or after January 1, 2011.
Sieco-Tech Canada Inc.
  • MR1-120MA-24
  • exclusively
AE-1760 Rev. 7 As per NOA Unconditional 10‑year initial reverification period for all meters.
TRIACTA Power Technologies, Inc. POWERHAWK 6320 AE-1434 Rev. 6 As per NOA Unconditional 10‑year initial reverification period for all meters.
TRIACTA Power Technologies, Inc.
  • PowerHawk 6312
  • PowerLogic E4880
  • PowerHawk 6312 Rev D
  • PowerLogic EM4880
AE-1665 Rev. 18 As per NOA Unconditional 10‑year initial reverification period for all meters.
TRIACTA Power Technologies, Inc. PowerHawk 6303D AE-1919 Rev. 15 As per NOA Unconditional 10‑year initial reverification period for all meters.
Table 2: Electricity meters qualified for a conditional 10-year initial reverification period, including electronic electricity meters subject to additional testing prior to the end of the 6-year initial reverification period
Manufacturer Model(s) Approval no. Configurations/Ratings Applicability
Intellimeter Canada Inc.
  • i-meter-MF3
  • i-meter-MF6
AE-2216 Rev. 1 As per NOA Conditional 10-year initial reverification period applicable to meters verified on or after
Sampling in accordance to S-S-05 required prior to June 2025.
Itron Inc. CP2SRA AE-2323 Rev. 7 As per NOA Sampling in accordance to S-S-05 required prior to June 2025.
Itron Inc.
  • CP3S
  • CP3SR
  • CP3SD
  • CP3ST
  • CP3SL
  • CP3SDR2
  • CP3STR2
  • CP3SLR2
  • CP3SDR3
  • CP3STR3
  • CP3SLR3
AE-2416 Rev. 2 As per NOA Conditional 10-year initial reverification period applicable to meters verified on or after January 17, 2019.
Sampling in accordance to S-S-05 required prior to June 2025.
Itron Inc.
  • C2SR
  • C2SRD
  • CN2SR
  • CN2SRD
AE-2425 Rev. 2 As per NOA Sampling in accordance to S-S-05 required prior to June 2025.
Sensus Metering Systems
  • BSA4
  • BNS4
AE-2450 Rev. 4 As per NOA Sampling in accordance to S-S-05 required prior to June 2026.
Sensus Metering Systems
  • SSA3
  • SSA4
AE-2258 Rev. 4 As per NOA Sampling in accordance to S-S-05 required prior to June 2024.
Table 3: Electronic electricity meters that no longer qualify for the conditional 10‑year initial reverification period or have not completed the sampling as required in accordance with S-S-05
Manufacturer Model(s) Approval no. Configurations/Ratings Applicability
Itron Inc. Q1000 AE-0828 Rev. 8 As per NOA Conditional 10‑year initial reverification period suspended. Initial reverification period amended to 6 years, applicable to all meters verified on or after January 1, 2003.
Power Measurement Ltd. / Schneider Electric
  • ION 6200
  • Siemens 9200
AE-1143 Rev. 4 As per NOA Qualification for the conditional 10-year initial reverification period suspended. Initial reverification period amended to 6 years, applicable to all meters verified on or after January 1, 2003.
Power Measurement Ltd. / Schneider Electric
  • ION 7550
  • ION 7650
  • Siemens 9510
  • Siemens 9610
AE-1484 Rev. 6 As per NOA Conditional 10-year initial reverification period qualification suspended. Initial reverification period amended to 6 years, applicable to all meters verified on or after January 1, 2003.
Power Measurement Ltd. / Schneider Electric
  • 8600 ION
AE-1535 As per NOA Conditional 10-year initial reverification period suspended. Initial reverification period amended to 6 years, applicable to all meters verified on or after January 1, 2003.

5.0 Revisions

The purpose of revision 17 was to add/modify the following to Tables 1 and 2:

  • Table 1: Moved AE-2269, AE-1589 and AE-2087 from Table 2.
  • Table 2: Added AE‑2450 and AE-2258; removed AE-2269, AE-1589 and AE-2087.

The purpose of revision 16 was to add/modify the following to Tables 1, 2 and 3:

  • Table 1: Moved E-0266, AE-1967, AE-2112, AE-2402 and AE-2220 from Table 2, added AE‑2537 and AE-2538 as the design was tested under different NOAs, and added AE‑1976, as the models were tested under that approval.
  • Table 2: Added AE-2216, AE-2416, AE-2425 and AE-2323; removed E-0266, AE-1967, AE‑2112, AE-2402 and AE-2220.
  • Tables 1, 2 and 3: Added information on exclusions and other clarifications to specific models; added to each approval number the hyperlink to the Notice of Approval database search page in order to provide access to the notice of approval so that the information on service configurations and ratings can be viewed.

The purpose of revision 15 was to add/modify the following to Tables 1 and 2:

  • Table 1: Added AE-1967, AE-2041, AE-2398, AE-1652, AE-1922 and added model iNA2 to AE‑1611; changed General Electric" to "Aclara Meters LLC".
  • Table 2: Added AE-2112 and AE-2402; removed AE-1922.

The purpose of revision 14 was to add/modify the following to Tables 1, 2 and 3:

  • Table 1: Added AE-1822, AE-2281, AE-1723, AE-1718, AE-1760, AE-1665 and AE-1919; modified AE-1631 and AE-1434.
  • Table 2: Added AE-2269 and AE-2220; modified AE-1922.
  • Table 3: Added AE-1652.

The purpose of revision 13 was to add the following to Tables 1 and 2 ( ):

  • Table 1: AE-1631, AE-1641
  • Table 2: AE-1665

The purpose of revision 12 was to add the following to Table 2:

  • AE-1589, AE-2087

The purpose of revision 11 was to add the following to Tables 1 and 2:

  • Table 1: AE-0924
  • Table 2: AE-1922, E-0266

The purpose of revision 10 was to add the following to Table 1:

  • AE1579, AE-0764, AE-1611

The purpose of revision 9 was to add the following to tables 1 and 2:

  • Table 1: AE-1498, AE-1148, AE-1559 and AE-1517
  • Table 2: AE-1718, AE-1641 and AE-1723

The purpose of revision 8 was to add additional configurations/ratings for AE-1466 and AE-1168, and to add the following information to Tables 1 and 2:

  • Table 1: AE-1466 and AE 1145
  • Table 2: AE-1148, AE-1652, AE-1631 and AE-1822

The purpose of revision 7 was to add AE-1434 to Table 1.

The purpose of revision 6 was to add AE-1356 to Table 1.

The purpose of revision 5 was to add/modify the following to Tables 2 and 3:

  • Table 2: Add additional configurations/ratings for the meters under AE-1517 and AE-1579.
  • Table 3: Include meters under AE-1145 to indicate a suspension of the lengthened initial reverification period until sampling pursuant to S-S-05 is completed.

The purpose of revision 4 was to add additional configurations/ratings for AE-1611 and AE‑0764 in Table 2.

The purpose of revision 3 was to add AE-1320 to Table 1 and include additional configurations for

AE-1611 in Table 2.

The purpose of revision 2 was to:

  • clarify and reflect the change in references from Measurement Canada provisional specification PS-E-11 to specification S-EG-01;
  • amend the scope to include meters that have been conditionally and unconditionally qualified to receive a 10-year initial reverification period, and meters that no longer qualify for a lengthened initial reverification period.